DP2 BATTERY REPLACEMENT E30 SERIES [6. BATTERY REPLACEMENT INSTRUCTIONS 2-24-2014]

Battery
Replacement
E30
Series
- Turn the Key Switch off. depress
the power disconnect, remove
cover as needed, this will
provide access to the batteries.
3. Disconnect the A/C battery
Charger cord and remove the
bracket.

5. Disconnect the Main Positive
location at the power fuse & the
Negative battery cable on the Pump
Motor.
6. Disconnect the Hydraulic and
pull through the frame.
8. Remove the four Assembly
mounting bolt located between
the Battery charger & Zapi controller.

9. With the 4 bolts removed, this will
allow for the complete assembly to be
swung out of the way . Once the panel
has been positioned, place a support
under the panel.
10. Now you can remove the battery
cables and swap out the batteries
A. main Negative
B. Jumper
C. Main Positive

11. Now the batteries can be swapped out

12. Install the New batteries and reassemble in the reverse order steps 10 thru 1